J Renal Inj Prev. 2016;5(2): 94-97.
doi: 10.15171/jrip.2016.20
PMID: 27471742
PMCID: PMC4962677
  Abstract View: 3725
  PDF Download: 1924

Original Article

Bioimpacts of dialyzer variety on phosphorus level in Iranian hemodialysis patients  

Aiyoub Pezeshgi 1,2, Bahareh Moharrami 2, Goodarz Kolifarhood 3, Alireza Sadeghi 2, Masoud Asadi-Khiavi 4,5*

1 Zanjan Metabolic Disease Research Center, Zanjan University of Medical Sciences, Zanjan, Iran
2 Department of Internal Medicine, School of Medicine, Zanjan University of Medical Sciences, Zanjan, Iran
3 Department of Epidemiology, School of Medicine, Zanjan University of Medical Sciences, Zanjan, Iran
4 Zanjan Applied Pharmacology Research Center, Zanjan University of Medical Sciences, Zanjan, Iran
5 Department of Pharmacotherapy, School of Pharmacy, Zanjan University of Medical Sciences, Zanjan, Iran
*Corresponding Author: *Corresponding author: Masoud Asadi-Khiavi, , Email: makhiavi@gmail.com

Abstract

Introduction: Cardiovascular events are the major cause of death in patients with chronic renal failure. About half of dialysis patients because of reduced phosphorus clearance have hyperphosphatemia. Hyperphosphatemia and following secondary hyperparathyroidism lead to some cardiovascular changes. Hemodialysis (HD) partly removes phosphorus during each dialysis session.

Objectives: Presented study was designed to evaluate dialyzer variation effect on phosphorus level as a prognostic factor after dialysis using.

Materials and Methods: Six kinds of dialyzer were used for dialysis; low flux (LF) dialyzer (F7 and F8), high flux (HF) dialyzer (F70 and F80) and finally hollow-fiber dialyzers including polyethersulfone (PES) 130 HF and polysulfone (PS) 13 LF. Fifty-seven patients were divided into 6 matched groups included three groups of 10 people and 3 groups of 9 persons in groups: A (F70), B (F80), C (F7), D (F8), E (PES 130 HF) and F (PS 13 LF). Patients were treated for one month with these dialyzers. At the end of the month, blood samples were taken again for phosphorus level before dialysis handling.

Results: The mean pre-dialysis serum phosphorus was 5.03, 5.4, 5.2, 4.6, 4.95 and 5.1 mg/dl and the mean phosphorus was 5.43, 5.01, 4.9, 4.18, 4.17 and 5.3 mg/dl after one month of dialysis, respectively in groups A to F without any statistically differences between pre- and after one month dialysis values respectively.

Discussion: The findings indicate dialyzer type in the control of serum phosphorus has not been effective in the short-term HD. We suggest a study with more duration time.

 

Implication for health policy/practice/research/medical education:

Dialyzer variety ineffectiveness on serum phosphorus level during short-term survey was revealed in presented study. On the other hand, it is concluded that the routine handling for phosphorus level without any care about dialyzer variety and following sticky situations (e.g. electrolytes and diet disturbances, drug interactions and caring about supplementary doses of needed drugs and so on) is enough for patient treatment at least in short time periods.

Please cite this paper as:Pezeshgi A, Moharrami B, Kolifarhood G, Sadeghi A, Asadi-Khiavi M. Bioimpacts of dialyzer variety on phosphorus level in Iranian hemodialysis patients. J Renal Inj Prev. 2016;5(2):94-97. DOI: 10.15171/jrip.2016.20

 
 